Trenchless Innovations has been providing air duct & sewer repair services to solve problems for residential and commercial clients in Wheaton, IL and the surrounding areas since 2002!
View our service reviews to see why our cutomers rate us highly as their trusted air duct & sewer repair professionals in Wheaton, IL.
Local Reviews
for Wheaton, IL
Our Reviews by City
Great service!
Pat - Wheaton, IL 60189
Response from Trenchless Innovations Inc.:
Pat, thank you for taking the time to let us know you had a great service experience with our team. We appreciate your business and are grateful for it. Thanks again!
Unique service that hopefully fixes my water issue
Rob - Wheaton, IL 60187
The workers were very respective and nice. They tried to keep the mess down and cleaned up after themselves.
Response from Trenchless Innovations Inc.:
Thank you for your review, Rob! We are happy to hear that our team didn't leave a mess in your home and cleaned up after completing the job. We are delighted you had a good experience with us and we thank you for your business. Please don't hesitate to reach out to us again should you have any further questions. Thanks again!
John R.
Cleaned 2” cast from laundry to open hole 12’, also cleaned 2” cast from open hole to where ties into 4” 20’. Lined 20’x2” from open hole to near toilet, also lined from open pipe near laundry 12’ to open hole, epoxy coated end of 2” inversion liner to 4” near toilet, also epoxy coated from toilet collar 3’ to liner from previous company.
Bob S.
Televised sewer from outside clean out 15 ft to city main. Provide proposal for lining.
Bob S.
Televised sewer from inside clean out in basement approximately 128 ft to city main. Cast iron under basement floor is very scaled and not allowing things to flow as much as they should. Recommend the installation of an outside clean out to allow for proper descaling of pipe and possible lining if necessary.
Bob S.
Cleaned all underground duct work in preparation for Trenchless casting. 11/13/24 Applied Trenchless spincast mortar to all underground ductwork and furnace 11/15/25 applied first coat of Duct Armor to all registers, plenum and duct runs. 11/22/24 Applied second application of duct armor to all underground ductwork and furnace box.
Bob S.
Televised ducts under slab floor. Ducts in living room is rusted through but the reminder of the ducts do not appear to be rusted. The run leading to the furnace from the living room is crushed in the garage area and would need to be duct up and replaced. The rest of the system can be spray lined with Duct Armor duct lining material.
John R.
Televised ducts from access under furnace. Ran water in kitchen and see it coming into the ducts. Also see water coming in when bathtub is run. Will provide quote to line sewer
Bob S.
Televised ducts under slab floor. Ducts are galvanized and rusted. Will send a revised proposal for spin cast mortaring and lining with Duct Armor.
Jim D.
Provide estimate to line approximately 40ft from newly installed outside clean-out to city main.
Kevin W.
-Inserted a 6” liner through the existing outside clean-out extending downstream approximately 70 feet to just before the city main. Reinstated 6” kitchen overhead connection. Inserted a 4-6” liner through the kitchen overhead clean out in the basement extending approximately 20’ ending prior to the main line that was just previously lined.
Bob S.
Air duct inspection service visit. Televised ducts under slab floor. Ducts are galvanized metal and are severely rusted and top of pipe is one near plenum. Recommended air duct repair. Suggest installing a sewer spot repair in pipe near the plenum then spin casting the rest of system and spray lining ducts with Duct Armor.
Josh R.
Cleaned all underground ductwork and repaired furnace box with hydraulic cement. Applied first application of duct armor to all underground ductwork.
Bob S.
Televised ducts under slab floor. Ducts are concrete ducts with metal fittings that look to be in good condition with Just sings of dirt and debris ar joints. Plenum is rusted. Provide proposal for spray lining ducts with Duct Armor duct lining material.
Josh R.
Televised underground 7” galvanized metal duct work. Ductwork is rusted and there is white dust throughout the system. We recommend applying spin cast mortar to the entire underground duct system. There is an area in the kitchen that might need to be broken up in order for us to access the air ducts and repair them correctly. There are signs of water in air ducts. Two areas in the ducts were damp. Recommend extending all downspouts 5’ away from the house.
Bob S.
Televised ducts under slab floor. Ducts are galvanized metal ducts and appear to be in good condition. Provide proposal for spray lining to encapsulate for radon.
Josh R.
Applied first application of duct armor to all underground duct work.
Josh R.
We are applying our Trenchless Cast Mortar to all of the heavily deteriorated underground galvanized metal duct work. This process will give the air ducts a strong concrete like structure and debris will no longer enter the system.
Kevin W.
We are cleaning all the underground duct work and applying two applications of our duct lining material to all the underground duct work.
Josh R.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
Josh R.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
Josh R.
We are cleaning all of the underground duct work in preparation for our duct encapsulation process. We are then going to apply the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
Josh R.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
Kevin W.
We are cleaning all the underground duct work in a home built on a concrete slab, and applying our rubberized duct lining material to all the underground duct.
Bob S.
Televised ducts under slab floor because of sewer smell in house. Found kitchen sink leaking into ducts and also tub and vanity leaking into ducts. Need plumber to fix drain lines then entire system should be retelevised to quote for encapsulation of ducts with Duct Armor duct lining material. Could not see ducts because of standing water at this time.
Josh R.
We are applying the second application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely encapsulated and the air in the home will be safe for the customer to breathe.
Josh R.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts. The air ducts will be completely encapsulated and the air in the home will be safe for the customer to breathe.