Trenchless Innovations provides air duct & sewer repair services that save property from significant digging or full duct replacement. We serve both residential and commercial clients of Steger, IL and the surrounding areas.
Read our reviews and find out why your neighbors and local businesses consider us to be their local, trusted sewer & duct repair company in Steger, IL.
Local Reviews
for Steger, IL
Our Reviews by City
Great service
Nancy - Steger, IL 60475
I have needed work done on my register vents for years,sand was coming up into my house through the vents I did not know there was a solution to my problem , especially so close to home! Everytime I asked a furnace rep about my issue. I was told I would have to get an upflow furnace and have to have vents put in my ceiling ! And at a cost of double what I paid to have my vents repaired! I wanted them repaired all along, but did not know about Trenchless until my house insurance rep told me of them. The whole crew was very professional they explained each step and left my house as neat as it was when they arrived I fully recommend this company to anyone having Issues with their vents!
Response from Trenchless Innovations Inc.:
Thank you for your review, Nancy! We are absolutely delighted to hear you not only received great customer service from our team but that we could effectively solve your sand in ducts problem for you. Thank you for choosing Trenchless Innovations for your air duct repair needs and we hope you're enjoying the cleaner, clearer air your repair made possible. Again, thank you for your business and for being a great customer. Please reach out to us again if you have any questions or need anything further. Thanks again!
Bob S.
Applied second coat of Duct Armor to all registers duct runs and plenum.
Bob S.
Duct lining service. Applied first coat of Duct Armor to all registers, plenum and duct runs.
Josh R.
Cleaned all underground duct work. Rebuilt all registers and plenum box with mortar. Applied Trenchless spin cast mortar to all underground duct work.
John R.
Looked at underground duct work heavy rust and sand, very little moisture /water present during tv. Need to clean blocked gutters and divert water away from house.
Bob S.
Televised ducts under slab floor. Ducts are concrete ducts With metal fittings and connections that are very rusted and deteriorated. Suggest spin cast mortaring then spray lining with Duct Armor duct lining material.
Bob S.
Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections that are allowing sand to enter into the line. Suggest spin cast mortaring of metal fitting and then spray line ducts with Duct Armor duct lining material.
Bob S.
Televised ducts under slab floor. Ducts are concrete possibly Transite with metal fittings and connections that are rusting and allowing sand to enter system. Suggest spin cast mortaring the joints then spray lining system with Duct Armor duct lining material.
Kevin W.
We are lining a sewer 73’ from an outside clean out out to the city main restoring the old clay tile pipe to like new PVC
Josh R.
We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated underground duct work.
Josh R.
We are applying the first application of our rubberized duct lining material to all of the heavily deteriorated underground duct work.
Kevin W.
We are applying our Trenchless cast mortar to all of the heavily deteriorated couplings that connect the underground duct work together. This will give these areas a strong concrete structure and sand and debris will no longer enter the system from these couplings. We will then completely seal the underground air duct system with two applications of our rubberized duct lining material.
Bob S.
Televised ducts under slab floor. Ducts are concrete with metal connections and fittings that are rusted and deteriorated. Suggest spin cast mortaring of the joints in order to restore structure. After that the ducts should be spray lining Ned with Duct Armor duct lining material.
Kevin W.
Televised sewer line to check condition of the pipe.
Kevin W.
Televised sewer line to check the condition of the pipe.
Kevin W.
Televising underground air ducts in a concrete slab, we found galvanized metal ducts are heavily rusted, we purposed the ducts can be repaired with our spin cast mortar system and then the duct armor product can be applied.
Kevin W.
Televising underground air ducts in a concrete slab, we found galvanized metal ducts are heavily rusted, we purposed the ducts can be repaired with our spin cast mortar system and then the duct armor product can be applied.
Kevin W.
Televising underground air ducts in a concrete slab, we found galvanized metal ducts are heavily rusted, we purposed the ducts can be repaired with our spin cast mortar system and then the duct armor product can be applied.
.
Restoring air duct Schaumburg, Illinois