Trenchless Innovations provides air duct & sewer repair services that save property from significant digging or full duct replacement. We serve both residential and commercial clients of Lansing, IL and the surrounding areas.

Read our reviews and find out why your neighbors and local businesses consider us to be their local, trusted sewer & duct repair company in Lansing, IL.

Local Reviews
for Lansing, IL

Trenchless Innovations Inc. Rated 5.0 out of 5 stars based on 1 customer reviews

Our Reviews by City



Great service




Review of Trenchless Innovations Inc.

LansingIL60438 41.5575-87.5625

Response from Trenchless Innovations Inc.:

Thank you for your review, Marilyn! We are happy to hear you had a pleasant experience with Josh and our team. Thank you for choosing Trenchless Innovations for your air duct lining. We hope you're enjoying the benefits of cleaner, healthier air it provides!


Bob S.

Bob S.

Televised ducts under slab floor. Ducts are concrete with metal fittings that are rusted and allowing sand to enter into the system. Propose to spin cast mortar over the joints then spray line system with Duct Armor duct lining material.

Near Park Ave, Lansing, IL 60438
Josh R.

Josh R.

Completed underground ducting repair by first televising the ducts to assess damage. Used high-pressure water jetting to clean the ducts thoroughly. Applied trenchless spincast mortar using a spin casting machine to restore structural integrity. Finally, spray-lined the ducts with Duct Armor material, ensuring a durable, corrosion-resistant coating for enhanced performance and longevity.

Near Thornton Lansing Rd, Lansing, IL 60438
Bob S.

Bob S.

Televised ducts under slab floor. Ducts are clay tile and concrete chase system. Ducts can be spray lined to try to keep smell out but it will not improve air in the rooms. Suggest possibly turning system overhead. Will provide quote for spray lining as a reference.

Near Wildwood Ave, Lansing, IL 60438
Kevin W.

Kevin W.

Performed sewer camera inspection for a Lansing, IL customer, revealing pipe degradation. Utilized advanced sewer lining methods to fortify affected areas, ensuring structural stability sans excavation. Customer satisfaction achieved; sewer system now restored.

Near Indiana Ave, Lansing, IL 60438
Bob S.

Bob S.

Ductwork video camera inspection service visit. Televised ducts under slab floor. Ducts are galvanized metal and are very rusted. Suggest spin cast mortaring to restore structure then spray lining ducts with Duct Armor duct lining material.

Near Lorenz Ave, Lansing, IL 60438
Bob S.

Bob S.

Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings and connections. There are multiple areas where the cardboard is collapsed and some of the elbows rusted. Provide proposal for possibly spin cast mortaring then spray lining ducts with Duct Armor duct lining material.

Near Sherman St, Lansing, IL 60438
Bob S.

Bob S.

Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections that are allowing sand to enter into the system. Suggest spin cast mortaring then spray lining with Duct Armor duct lining material.

Near Roy St, Lansing, IL 60438
Bob S.

Bob S.

Televised ducts under slab floor. Ducts are clay tile pipes and have sand entering into the pipes through the joints at every two feet. Suggest spin cast mortaring and spray lining ducts with Duct Armor duct lining material to seal off the jouints and provide a clean healthy breathing environment.

Near Roy St, Lansing, IL 60438
Josh R.

Josh R.

We are applying the second application of our rubberized duct lining material to all of the heavily deteriorated underground duct work.

Near Rose St, Lansing, IL 60438
Josh R.

Josh R.

We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.

Near Rose St, Lansing, IL 60438
Bob S.

Bob S.

Televised ducts under slab floor. Ducts are cardboard ducts with metal fittings and connections. Cardboard is collapsed in several spots. Provide proposal for spin cast mortar and spray lining ducts with Duct Armor duct lining material.

Near Henry St, Lansing, IL 60438
Bob S.

Bob S.

Televised ducts under slab floor. Ducts are concrete possibly Transite asbestos ducts with metal connections and fittings that are rusting and deteriorated. Water supply s entering ducts through the connections. Suggests installing inside drain tile that a newly installed sump pit and pump to control the water. After the water issue s resolved the ducts should be spray lined with Duct Armor duct lining material.

Near 185th Ct, Lansing, IL 60438
Bob S.

Bob S.

Televising underground air ducts under slab floors. Ducts are cardboard ducts and are showing heavy signs of deterioration and water damage. Ducts need to be spin cast mortared to restore the structure. We will then spray line with Duct Armor duct lining material.

Near Henry St, Lansing, IL 60438
Jim D.

Jim D.

Lining sewer from overhead clean out. Sewer water is leaking out of pipe and back into basement through crack in foundation. Lining will seal joints and cracks.

Near William St, Lansing, IL 60438
Lansing, IL - Lining sewer from overhead clean out. Sewer water is leaking out of pipe and back into basement through crack in foundation. Lining will seal joints and cracks.