Customers say: The reviews exhibit a positive sentiment, with most customers expressing satisfaction with the services provided. The recurring themes include professionalism, courtesy, respect, efficiency, and expertise. Customers appreciate the team's ability to explain the process, answer questions, and provide excellent service. The positive reviews highlight the team's professionalism, punctuality, and neatness, with some customers referring to them as respectful and polite. The negative reviews are minimal, with some customers mentioning minor issues that were promptly addressed. Overall, the sentiment is positive, with customers expressing gratitude and recommending the company for future projects.

Our Local Reviews by City

Job Locations and Reviews

 .
. Checked in
Conducted sewer video inspection at residential property in Hobart. Client reported recurring backups in basement fixtures despite multiple routine cleanings by previous service providers. Deployed high-definition sewer camera from basement cleanout access point. Line is 6-inch clay pipe transitioning to city connection at approximately 65 feet. Inspection revealed multiple issues: significant root intrusion at 18 feet and 43 feet from access point penetrating through pipe joints; partial collapse at 38 feet creating approximately 30% restriction in flow capacity; and improper grade between 50-60 feet creating standing water and debris accumulation. Notable mineral buildup observed throughout system indicating history of water treatment discharge. Total line length to city connection measured at 72 feet. Provided customer with comprehensive digital recording of inspection with professional narration identifying all deficiencies. Recommended trenchless pipe lining as most cost-effective
Hobart, IN 46342
Josh R.
Josh R. Checked in
Performed a televised inspection of the underground air ducting to identify any damage or gaps for a customer in Hobart, IN. After the inspection, the ducts were thoroughly sealed to prevent air leaks and improve system efficiency. This sealing process stops air loss, protects against moisture and contaminants, and enhances airflow. Sealing the underground ducts also prevents dirt, mold, and pests from entering, ensuring cleaner air quality and better HVAC performance. The televised service ensures precise detection and targeted repairs.
Hobart, IN 46342
Review
Great service!! Explained all questions I asked where I could understand. Also very helpful and polite!
Glenda - Hobart, IN 46342
Response from Trenchless Innovations Inc.:

Thank you so much for this 5-star review. We really appreciate you being a customer and helping to share the word about us. We’re here for you anytime.

Bob S.
Bob S. Checked in
Televised ducts under slab floor. Ducts are PVC ducts with metal fittings. There was water in the lines on the right sid of the house. There was also a sump pump in the plenum. Downspouts need to be corrected and grading is not correct. Need to raise pitch by house for patio in courtyard.
Hobart, IN 46342
Bob S.
Bob S. Checked in
Televised ducts under slab floor. Ducts are pvc coatefc metal ducts. There is standing water in the plenum and main duct run. There are changes outside with downspouts and grading that need to be made. After the water is resolved then the ducts should be spray lined with Duct Armor duct lining material.
Hobart, IN 46342
Bob S.
Bob S. Checked in
Televised ducts under slab floor. Ducts are concrete ducts possibly Transite with metal fittings and connections. Sand entering into ducts from the metal fittings. Suggest. Spin cast mortaring metal fittings then spray lining ducts with Duct Armor duct lining material. Make senior citizen discount.
Hobart, IN 46342
Bob S.
Bob S. Checked in
Televised ducts under slab floor. Ducts are pvc coated metal. Sand is being drawn int the pipe through the joints. Suggest spray lining with Duct Armor duct lining material.
Hobart, IN 46342
Request Service
servicedetailscustomerreturningschedule
*
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
*
What Is Convenient For You?
*
What time of day is best for you?
First Available
Morning
Afternoon
*

Call For Same Day Service/Emergencies at 708-758-5070 .

By pressing Submit I agree to receive phone, email, or text messages from Trenchless Innovations to the provided mobile number and also agree to the Trenchless Innovations terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next