Trenchless Innovations provides air duct & sewer repair services that save property from significant digging or full duct replacement. We serve both residential and commercial clients of Palatine, IL and the surrounding areas.
Read our reviews and find out why your neighbors and local businesses consider us to be their local, trusted sewer & duct repair company in Palatine, IL.
Local Reviews
for Palatine, IL
Our Reviews by City
Bob S.
Televised ducts under the slab floor and found cardboard ducts. The return duct might be concrete due to its size, but access was limited by the register size. Suggest spin cast mortaring to restore structure, followed by spray lining with Duct Armor duct lining material for durability and improved performance.
Josh R.
Performed sewer preparation by cleaning and measuring the pipe. On 7-5-24, inserted a Perma-Liner™ resin-saturated liner through the existing exterior cleanout. The liner extended approximately 80 feet, stopping just before the city main. Used an inversion drum for liner insertion and cured it in place with steam, creating a seamless and durable internal pipe repair.
Bob S.
Televised sewer from. Outside clean out to main at 80ft. Provided proposal for lining from clean out to main.
Jim D.
This morning I'm working in Inverness, IL for a wonderful client. I applied the initial coat of RS-100 to all underground ductwork. This specialized coating serves as a protective barrier, safeguarding the ducts against corrosion and extending their lifespan. The application process involved thorough cleaning of the duct surfaces before evenly applying the RS-100 coating. This proactive measure ensures the durability and efficiency of the underground duct system for years to come.
Bob S.
Televised ducts under slab floor. Ducts are galvanized meta and are showing signs of rust in lower level of the house. Suggest spin cast mortaring lower level then spray lining entire system with Duct Armor duct lining material.
Bob S.
Slab leak detection service call. Televised ducts under slab floor. Ducts are cardboard ducts. The run in the family room has dropped and is no longer lined up. Will provide proposal for blocking off the space around duct and then spin cast mortaring and duct lining.
John R.
2-14-2023: Cleaned and measured in preparation for lining, did not install spot repair liner at 24’ mark used pan and tilt camera to verify its not a break but a cross connection and need to get OK from city that the tie in’s are dead and can be lined/ covered over. 3-31-2023: installed spot repair liner over cross connection in street before city main where pipe was heavily cracked and had heavy root growth, also lined 6” clay sewer 35’ to city main starting liner in 6” pvc just downstream of clean out and ended liner in 6” clay just before city main.
Josh R.
We are applying the first application of our rubberized duct lining material to all of the underground asbestos transite air ducts.
Josh R.
Rebuilt all register vents with hydraulic cement. Applied first application of duct armor to all underground ductwork.
Josh R.
Televised ducts under slab floor. Ducts are concrete ducts with metal fittings and connections. Provide proposal for spray lining ducts with Duct Armor duct lining material.
Josh R.
We are applying the first application of our rubberized duct lining material to all of the rusted underground galvanized metal duct work.
Bob S.
Televised ducts under slab floor. Ducts are PVC with metal fittings and connections. No standing water at the time of inspection but there were water marks indicating water has been in the ducts. The elbow under the foyer from the vent near the front door is broke allowing stone to enter the ducts. This would need to be dug to be replaced. Downspouts need to be extended all around the building and some type of retaining wall installed to prevent water from accumulating next to sliding glass door.
Josh R.
We are televising underground pvc air ducts that have water throughout the system. We are going to look at all of the water issues and give the customer a solution for the problem.
Bob S.
Televised ducts under slab floor ducts are concrete ducts with metal fittings and connections. Due to elevated radon levels in the house suggest sealing the ducts by spray lining ducts with Duct Armor duct lining material.
Bob S.
Televised ducts under slab floor. Ducts are pvc with metal connections. There had been a sewer break that had contaminated the line. Suggest spray lining ducts to encapsulate.
Kevin W.
We are cleaning all the underground duct work, installing a 3’ spot repair liner in the main line where a breach in the pipe was allowing the gravel back fill to fall in and block air flow off for the bedrooms, and also sealing the entire underground duct work with our duct lining product.
Bob S.
Televised ducts under slab floor. Ducts are galvanized metal and showing slight signs of rust. No water was visible in the system at the time of inspection. Customer needs to extend downspouts away in the back of the house and also inspect gutters for proper flow. Suggest spray lining ducts with Duct Armor duct lining material.